Home > Products > Pocket-Sized Instruments >

SpectraPen SP 100

SpectraPen SP 100 is a handheld spectrometer that's ideal as a general-purpose instrument for research labs, agricultural and industrial applications. SP 100 is especially useful for rapid measurements of solar irradiance and monitoring of spectral light quality.

SP 100 works with Li-Ion rechargeable battery and does not require any PC or any other bulky accessory. Instead, wavelength and intensity readings and their spectral lines are instantly displayed on the SpectraPen touch screen display. All recorded data are automatically stored into the device internal memory. The SpectraPen also includes an integrated GPS module and comprehensive software package including full system control, data acquisition and data processing.

SpectraPen SP 100 is available in two models:
- SpectraPen SP 100-UVIS with wavelength range 340 to 780 nm
- SpectraPen SP 100-NIR with wavelength range 640 to 1050 nm.

See also the enhanced device version SpectraPen LM 500 with calibrations for key irradiance units, like Lux, Lumen, PAR, Watt, etc., as well as Poly-PlantPen RP 400 comprising complete setup for measuring leaf reflectance parameters.

  • Handheld and lightweight with affordable price
  • Programmable via intuitive touch-screen use
  • Wide spectral response range: UV/Vis 340-780 nm; NIR: 640-1050 nm
  • Both lab and field application
  • Battery-powered
  • USB connectivity
  • Integrated GPS module
  • SpectraPen
  • SP 100-UVIS: range 340-780 nm
  • SP 100-NIR: range 640-1050 nm
  • Optional specific setups for fluorescence or reflectance will be released soon
  • Indoor and outdoor visible light source testing
  • Optical filters and protecting screens spectra measurements
  • Quality of artificial lighting
  • Wavelength (light color) measurement
  • Reflectance, transmittance, fluorescence, absorption of various samples (external sample holder and light source needed)
  • SpectraPen
  • Scope – rough spectrum data
  • Absorbance (external sample holder and light source needed)
  • A=log(I0/I), where I0 is reference light intensity and I is measured light intensity
  • Transmittance (external sample holder and light source needed)
  • T= I/I0, where I0 is reference light intensity and I is measured light intensity
  • Different operation modes: scope, absorbance, transmittance
  • Different tools: zoom, marker, auto scale, curve smoothing
  • Automated setting of the integration time
  • Data browsing and data averaging
  • Visualization and data transfer routines to Microsoft Excel
  • GPS mapping plug-in (optional)
  • SpectraPen
    Measured Spectra Lines: White, Blue, Red LEDs and Sunlight.
  • Optical Entrance:
    SMA 905 to 0.22 numerical aperture single-strand optical fiber
  • Spectral Response Range:
    SP 100-UVIS: 340 nm - 780 nm
    SP 100-NIR: 640 nm - 1050 nm
  • Spectral Response Half Width:
    SP 100-UVIS: 9
    SP 100-NIR: 8
  • Spectral Straylight*:
    -30 dB
  • Wavelength Reproducibility:
    +/- 0.5 nm
  • Integration Time:
    5 ms to 10 s
  • Number of Pixel:
    256
  • Dimension of Pixel:
    0.5 x 15.8 mm
  • Touch Screen:
    240 x 320 pixel; 65535 colors
  • Memory Capacity:
    32 Mbit (up to 4000 measurements)
  • System Data:
    16 bit AD conversion
  • Dynamic Range:
    High gain: 1:4300; Low gain: 1:13000
  • Communication:
    USB
  • Dimension:
    15 x 7.5 x 4 cm
  • Weight:
    300 g
  • Case:
    Splash-proof
  • Battery:
    Li-ion; rechargeable via USB port of a PC
  • Battery Life:
    48 hours (continuous operation)
  • Operating Temperature:
    0 to +50 ºC
  • Storage Temperature:
    -20 to +70 ºC
  • Warranty:
    1 year parts and labor
  • DĄBROWSKI P., PAWLUŚKIEWICZ B., BACZEWSKA A. H. ET AL. (2015): Chlorophyll a fluorescence of perennial ryegrass (Lolium perenneL.) varieties under long term exposure to shade. Zemdirbyste-Agriculture. Volume 102, Pages 305-312. DOI 10.13080/z-a.2015.102.039
  • DĄBROWSKI P., CETNER M. D., SAMBORSKA I. A. ET AL. (2015): Measuring light spectrum as a main indicator of artificial sources quality. Journal of Coastal Life Medicine. Volume 3, Pages 398-404. DOI:10.12980/JCLM.3.2015J5-25

Pricing

  • Orders and Payments
  • SpectraPen SP 100
    2.999,- €
  • Mini-Computer *
    390,- €
  • Cosine Corrector for SpectraPen
    150,- €

SpectraPen Versions

SpectraPen SP 100 UVIS
Spectral response range: 340 to 780 nm.


SpectraPen SP 100 NIR
Spectral response range: 640 to 1050 nm.

Optional Features and Accessories

Mini-Computer
Small, portable notebook (type according to current availability on the market).


Cosine Corrector
Cosine corrector for emission collection.

Download

Software
FluorPen 1.0
OS: Windows 2000 / Windows XP / Windows 7 (32bit, 64bit) / Windows 8 (32 bit, 64bit)/ Windows 10 (32 bit, 64bit),
Language: English
Size: 11.1 MB


SpectraPen_PolyPen 1.0.0.7
OS: Windows 7 (32bit, 64bit) and higher
Language: English
Size: 901 KB


USB Driver for Pen Devices
OS: Windows
Language: English
Size: 2.0 MB


Documents
FluorPen Series Manual
Type: PDF
Language: English
Size: 4.7 MB


FluorPen - List of References
Type: PDF
Language: English
Size: 779 KB


FluorPen Explain
Type: PDF
Language: English
Size: 2.8 MB


SpectraPen SP 100 Manual
Type: PDF
Language: English
Size: 1.4 MB


SpectraPen SP 100 - List of References
Type: PDF
Language: English
Size: 131 KB


SpectraPen LM 500 Manual
Type: PDF
Language: English
Size: 2.9 MB


PolyPen Manual
Type: PDF
Language: English
Size: 2.2 MB


PolyPen - List of References
Type: PDF
Language: English
Size:


AquaPen Manual
Type: PDF
Language: English
Size: 4.1 MB


AquaPen Manual (Czech)
Type: PDF
Language: English
Size: 4.0 MB


AquaPen - List of References
Type: PDF
Language: Czech
Size: 1.1 MB


LaiPen Manual
Type: PDF
Language: English
Size: 2.0 MB


LaiPen - List of References
Type: PDF
Language: English
Size: 135 KB


N-Pen Brief Guide
Type: PDF
Language: English
Size: 104 KB


N-Pen - List of References
Type: PDF
Language: English
Size:


PlantPen NDVI-PRI Operation Manual
Type: PDF
Language: English
Size: 2.7 MB


PlantPen - List of References
Type: PDF
Language: English
Size: 181 KB


Other Pocket-Sized-Instruments

FluorPen FP 100

FluorPen is a hand-held fluorometer that measures chlorophyll fluorescence parameters in a fully automated and rapid manner.
Applications:
- Photosynthesis Research & Education
- Large plant screening programs
- Agriculture & Forestry
- Biotechnology


PAR-FluorPen FP 100-MAX-LM

PAR-FluorPen is used to measure fluorescence and Photosynthetic Photon Flux Density (PPFD) of photosynthetically active radiation (PAR).
Applications:
- Photosynthesis Research & Education
- Plant & Molecular Biology
- Agriculture & Forestry
- Biotechnology


Monitoring Pen MP 100

Monitoring Pen is a robust and weather-proof version of the popular FluorPen that is intended for unattended use in a field.
Applications:
- Photosynthesis Research & Education
- Long-Term, Autonomous Fluorometry Experiments


AquaPen-C AP-C 100

AquaPen-C is a new cuvette version of the popular FluorPen fluorometer. It is optimized for measuring chlorophyll fluorescence in green algae and cyanobacteria. AquaPen sensitivity 500 ng Chl/l enables measuring in natural water.
Applications:
- Photosynthesis Research & Education
- Biotechnology
- Limnology & Oceanography


AquaPen-P AP-P 100

AquaPen-P is equipped with a submersible optical probe. It suits investigations in algal suspensions and natural waters. AquaPen sensitivity: 500 ng Chl/l.
Applications:
- Photosynthesis Research & Education
- Phycology
- Limnology & Oceanography
- Biotechnology


SpectraPen LM 500

SpectraPen with precise radiometric calibration and integrated cosine corrector. Number of formulas and calculated parameters: PAR, Watt, Lux, Lumen, CIE color coordinates, color rendering indexes, color temperatures.
Applications:
- Light Characteristics Measurements
- Light Source Testing and Quality Control
- Color Measurement


SpectraPen SP 100

SpectraPen is a handheld, programmable spectrophotometer that provides instant readings and spectral lines on interactive touch screen.
Applications:
- Visible Light Source Testing
- Color Measurement
- Chemical Measurement


PolyPen RP 400

PolyPen RP 400 is a complete system for measurement of spectral reflectance on flat leaves as well as measurements of transmittance and absorbance of any external light source. Integrated software is capable of automatic calculation of all common vegetation indices.


PlantPen PRI 200 & NDVI 300

PlantPen is a low-cost, handheld device that characterizes plants by means of reflectance. The two standard versions measure PRI and NDVI.
Applications:
- Photosynthesis Research & Education
- Vegetation Productivity
- Vegetation Stress Studies
- Agriculture


N-Pen N 100

N-Pen is a light-weight, battery-powered instrument that provides quick measurement of actual nitrogen content in plants throughout their growing season.
Applications:
- Significant Yield Increase
- Quick Tuning of Nitrogen Management in Crops
- Saving Nitrogen Application Costs


LaiPen LP 100

LaiPen is a light-weight, battery-powered device that mesures Leaf Area Index (LAI) and Photosynthetically Active Radiation (PAR). It provides fast and easily repeatable measurements with instant readouts that can be exported to a PC for further processing.
Applications:
- Studies of Canopy Productivity
- Studies of Forest Dynamism
- Remote Sensing


Video Gallery